ProCalida® MC 1

AFRISO Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK FM VOR 110820 110830 110840 110850 110860 110870 110880 110890 110900 110910 110920 object_image_98775imagemain_en AFRISO Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK FM VOR 110820 110830 110840 110850 110860 110870 110880 110890 110900 110910 110920 object_image_98775imagemain_en
Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK FM
AFRISO Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK FM VOR 110820 110830 110840 110850 110860 110870 110880 110890 110900 110910 110920 object_image_98775imagemain_en
AFRISO Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK SV VOR 110940 110950 110960 110970 110980 110990 111000 111010 111020 111030 111040 111060 111070 111080 111090 111100 111110 111120 111130 111140 111150 111160 AFRISO Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK SV VOR 110940 110950 110960 110970 110980 110990 111000 111010 111020 111030 111040 111060 111070 111080 111090 111100 111110 111120 111130 111140 111150 111160
Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK SV
AFRISO Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK SV VOR 110940 110950 110960 110970 110980 110990 111000 111010 111020 111030 111040 111060 111070 111080 111090 111100 111110 111120 111130 111140 111150 111160
AFRISO Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK FM VOR 110820 110830 110840 110850 110860 110870 110880 110890 110900 110910 110920 object_image_98775imagemain_en
AFRISO Kunststoff-Heizkreisverteiler ProCalida MC 1 2-HK SV VOR 110940 110950 110960 110970 110980 110990 111000 111010 111020 111030 111040 111060 111070 111080 111090 111100 111110 111120 111130 111140 111150 111160
Data sheet ProCalida® MC 1
AFRISO Data sheet ProCalida® MC 1

Versions

Number of heating circuits Part no. Remember
ProCalida® MC 1 2-HK FM 2 77222
ProCalida® MC 1 3-HK FM 3 77223
ProCalida® MC 1 4-HK FM 4 77224
ProCalida® MC 1 5-HK FM 5 77225
ProCalida® MC 1 6-HK FM 6 77226
ProCalida® MC 1 7-HK FM 7 77227
ProCalida® MC 1 8-HK FM 8 77228
ProCalida® MC 1 9-HK FM 9 77229
ProCalida® MC 1 10-HK FM 10 77230
ProCalida® MC 1 11-HK FM 11 77231
ProCalida® MC 1 12-HK FM 12 77232

Blue part no. = in-stock items

Number of heating circuits Part no. Remember
ProCalida® MC 1 2-HK SV 2 77202
ProCalida® MC 1 3-HK SV 3 77203
ProCalida® MC 1 4-HK SV 4 77204
ProCalida® MC 1 5-HK SV 5 77205
ProCalida® MC 1 6-HK SV 6 77206
ProCalida® MC 1 7-HK SV 7 77207
ProCalida® MC 1 8-HK SV 8 77208
ProCalida® MC 1 9-HK SV 9 77209
ProCalida® MC 1 10-HK SV 10 77210
ProCalida® MC 1 11-HK SV 11 77211
ProCalida® MC 1 12-HK SV 12 77212

Blue part no. = in-stock items

Number of heating circuits Part no. Remember
ProCalida® MC 1 2-HK Vario-DP 2 77072
ProCalida® MC 1 3-HK Vario-DP 3 77073
ProCalida® MC 1 4-HK Vario-DP 4 77074
ProCalida® MC 1 5-HK Vario-DP 5 77075
ProCalida® MC 1 6-HK Vario-DP 6 77076
ProCalida® MC 1 7-HK Vario-DP 7 77077
ProCalida® MC 1 8-HK Vario-DP 8 77078
ProCalida® MC 1 9-HK Vario-DP 9 77079
ProCalida® MC 1 10-HK Vario-DP 10 77080
ProCalida® MC 1 11-HK Vario-DP 11 77081
ProCalida® MC 1 12-HK Vario-DP 12 77082

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet ProCalida® MC 1 Data sheet PDF
AFRISO Data sheet ProCalida® MC 1
Heating circuit manifold ProCalida MC 1 Operating instructions PDF
AFRISO Heating circuit manifold ProCalida MC 1
ProCalida® MC 1 Flyer PDF
AFRISO ProCalida® MC 1
Heating circuit manifold ProCalida Flyer PDF
AFRISO Heating circuit manifold ProCalida
Heating circuit manifold ProCalida Technical specifications manifolds, heating/cooling circuits PDF
AFRISO Heating circuit manifold ProCalida
Heating circuit manifold ProCalida Pre-adjustment water volume for Vario-DP PDF
AFRISO Heating circuit manifold ProCalida

Robust, very short plastic heating or cooling circuit manifold with up to 12 heating circuits. Return with stroke valves for actuators. Return valves with dual O ring seal at the valve axis for particularly long running times with optimum sealing. Valve disc with O ring seal for permanently reliable closing of the control circuits. Flow bar with flow meters that can be shut off. Control range flow meter 0.5 to 4 l/min with locking as per EN 1264-4. The valves can be shut off and regulated for hydraulic balancing of wall or underfloor heating systems. When the system is shut off, the pre-adjustment is not lost for compliance with EN 1264-4. Windows can be cleaned and replaced with system pressure present. Main connection with union nut G1. With filling and drain valve, manual vent and thermometer. Quick air vent can be fitted using a lifting tool. Connection by means of angular connection pieces and/or ball valve G1 adapted to the manifold. With dovetail guide at both ends for fast snap-in mounting and horizontal movement of the wall bracket.

The wall bracket is made of plastic for excellent sound absorbing characteristics. Suitable for standard manifold cabinets. With adjustable distance between the flow and return bars, for easy, collision-free mounting even in the case of large actuator and heating circuit pipes up to 20 mm. The AFRISO manifold systems are 100 % tightness-tested and function-tested.

Number of heating/cooling circuits
2 – 12
Medium
Heating circuit water and cooling circuit water as per VDI 2035
(Water/glycol mixtures with an admixture of max. 50 %)
Test pressure
Max. 6 bar
Main connection
G1 flat-sealing, with union nut
Connection from the right or from the left
Connection heating/cooling circuit
G¾ male thread, eurocone
Suitable for standard compression fittings
Operating temperature range
Medium:
-20/+90 °C at 3 bar,
-20/+60 °C at 6 bar
Flow coefficient Kvs
1.56 m³/h
1.3 m³/h
1 m³/h
Flow meter
Can be shut off and regulated, with pre-adjustable adjustment ring
Range:
0.5/4 l/min
Mounting position:
Any
Accuracy:
± 10 %, with reference to the full scale value
Return valves
Mating thread:
M 30 x 1.5 mm
Closing force:
< 70 N
Closing dimension:
12 ± 0.6 mm
(open position 15 mm)
Wall bracket
Suitable for standard manifold cabinets
Options
  • Wall bracket with fixed distance
  • With dynamic control valves Vario-DP in the return
Click the corresponding image for detail views, additional information and dimension tables.
Version with flow meter (FM)
Version with flow meter (FM)
AFRISO
Dimensions (mm):
Heating circuit 2 HK 3 HK 4 HK 5 HK 6 HK 7 HK 8 HK 9 HK 10 HK 11 HK 12 HK
A (mm) 50 50 100 150 200 200 250 300 300 350 350
B (mm) 43 68 68 68 68 118 118 118 118 118 168
L (mm) 185 235 285 335 385 435 485 535 585 635 685
Version with shut-off valve (SV) or dynamic control valve
Version with shut-off valve (SV) or dynamic control valve
AFRISO
Dimensions (mm):
Heating circuit 2 HK 3 HK 4 HK 5 HK 6 HK 7 HK 8 HK 9 HK 10 HK 11 HK 12 HK
A (mm) 50 50 100 150 200 200 250 300 300 350 350
B (mm) 43 68 68 68 68 118 118 118 118 118 168
L (mm) 185 235 285 335 385 435 485 535 585 635 685