pH value/determination of conductivity WQ 10

AFRISO pH-/Leitfähigkeitssensor CAPBs sens WQ 10 VOR 2870 22900 object_image_81403imagemain_en AFRISO pH-/Leitfähigkeitssensor CAPBs sens WQ 10 VOR 2870 22900 object_image_81403imagemain_en
pH-/Leitfähigkeitssensor CAPBs sens WQ 10
AFRISO pH-/Leitfähigkeitssensor CAPBs sens WQ 10 VOR 2870 22900 object_image_81403imagemain_en
AFRISO pH-/Leitfähigkeitssensor CAPBs sens WQ 10 VOR 2870 22900 AFRISO pH-/Leitfähigkeitssensor CAPBs sens WQ 10 VOR 2870 22900
pH-/Leitfähigkeitssensor CAPBs sens WQ 10
AFRISO pH-/Leitfähigkeitssensor CAPBs sens WQ 10 VOR 2870 22900
AFRISO Sensorkopf pH, EC, SAL, TDS, Temperatur VOR 22620 22880 AFRISO Sensorkopf pH, EC, SAL, TDS, Temperatur VOR 22620 22880
Sensorkopf pH, EC, SAL, TDS, Temperatur
AFRISO Sensorkopf pH, EC, SAL, TDS, Temperatur VOR 22620 22880
AFRISO pH-/Leitfähigkeitssensor CAPBs sens WQ 10 VOR 2870 22900 object_image_81403imagemain_en
AFRISO pH-/Leitfähigkeitssensor CAPBs sens WQ 10 VOR 2870 22900
AFRISO Sensorkopf pH, EC, SAL, TDS, Temperatur VOR 22620 22880
Data sheet pH value/determination of conductivity WQ 10
AFRISO Data sheet pH value/determination of conductivity WQ 10

Versions

Part no. Remember
PH/conductivity sensor CAPBs® sens WQ 10 M090251310
Sensor head pH, CON, SAL, TDS, TEMP 524353

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet pH value/determination of conductivity WQ 10 Data sheet PDF
AFRISO Data sheet pH value/determination of conductivity WQ 10
Simultaneous determination of the pH value, the electrical conductivity and the water hardness (German hardness) with a single measurement. Determination of the total hardness is not possible in the case of chemically treated water or water softened by means of ion exchange. In addition, the TDS value (total dissolved solids in the water), salinity and temperature can be output. Thanks to automatic temperature compensation and measuring range switching, the conductivity can be measured with a high measuring accuracy.
Dimensions (W x H x D)
Sensor module:
43 x 130 x 36 mm
Weight
pH/conductivity sensor CAPBs® sens:
56 g
Measuring range
Conductivity:
0/50,000 µS/cm
Salinity:
0/25,000 ppm
TDS:
0/50,000 mg/l
PH value:
0/14 pH
Temperature:
-5/+60 °C
Accuracy
Conductivity:
± 2 µS/cm (0/199 µS/cm)
± 5 µS/cm (200/499 µS/cm)
± 20 µS/cm (500/1,999 µS/cm)
± 0.2 mS/cm (2/19.99 mS/cm)
± 0.5 mS/cm (20/50 mS/cm)
TDS:
± 10 mg/l
PH value:
± 0.01 pH
Temperature:
± 0.5 K
Resolution
Conductivity:
1 µS/cm
Salinity:
0.1 ppm
TDS:
1 mg/l
PH value:
0.01 pH
Temperature:
0.1 °C
Indication of measured values
Conductivity:
µS/cm, mS/cm
Salinity:
ppm, ppt
TDS:
mg/l, g/l
Hardness:
°d, °e, °f, °rH, ppm, mg/l, mmol/l, mol/m3
PH:
pH
Temperature:
°C, °F