Guided micropulse level indicators PulsFox® PMG 20

 BEF 73320  BEF 73320
 BEF 73320 <div class="gallery-information"> <p> <strong>PulsFox<sup>®</sup> PMG 20 MS - 20-with rigid mono probe</strong> </p> <p>Dimensions (in mm)</p> <b>Legend:</b> <ol> <li>Electrode holder</li> <li>Electrode</li> </ol> </div>
 BEF 73410 73420  BEF 73410 73420
 BEF 73410 73420 <div class="gallery-information"> <p> <strong>PulsFox<sup>®</sup> PMG 20 KX - 40 with coax probe</strong> </p> <p>Dimensions (in mm)</p> <b>Legend:</b> <ol> <li>4 x opening</li> </ol> </div>
 BEF 73460 73470  BEF 73460 73470
 BEF 73460 73470 <div class="gallery-information"> <p> <strong>PulsFox<sup>®</sup> PMG 20 - 62/63 mounting eyelet</strong> </p> <p>Dimensions (in mm)</p> <b>Legend:</b> <ol> <li>Mounting</li> </ol> </div>
 SAL 73290 73300 73320 73330 73340 73350 73360 73370 73380 73390 73410 73420 73440 73450 73460 73470 73480 73490 73500 73510 object_image_87616imagemain_en
 SAL 73320
 SAL 73410 73420
 SAR 73320
 SAR 73410 73420
 73290 73300 73320 73330 73340 73350 73360 73370 73380 73390 73410 73420 73440 73450 73460 73470 73480 73490 73500 73510
 RUE 73320
 RUE 73410 73420
 ANW 73290 73300 73320 73330 73340 73350 73360 73370 73380 73390 73410 73420 73440 73450 73460 73470 73480 73490 73500 73510
 BEF 73290 73300
 BEF 73290 73300 73320 73330 73340 73350 73360 73370 73380 73390 73410 73420 73440 73450 73460 73470 73480 73490 73500 73510
 BEF 73290 73300 73320 73330 73340 73350 73360 73370 73380 73390 73410 73420 73440 73450 73460 73470 73480 73490 73500 73510
 BEF 73320
 BEF 73330
 BEF 73340 73350
 BEF 73410 73420
 BEF 73450
 BEF 73460 73470
 BEF 73460 73470
Data sheet Guided micropulse level indicators PulsFox® PMG 20
AFRISO Data sheet Guided micropulse level indicators PulsFox® PMG 20

Versions

Part no. Remember
PulsFox® PMG 20 MO -00 5654000O-L-101
PulsFox® PMG 20 MO -00 with local display 5654000D-L-101
PulsFox® PMG 20 MS -20 5654020O-L-101
PulsFox® PMG 20 MS -21 5654021O-L-101
PulsFox® PMG 20 MS -22 5654022O-L-101
PulsFox® PMG 20 MS -23 5654023O-L-101
PulsFox® PMG 20 MS -20 with local display 5654020D-L-101
PulsFox® PMG 20 MS -21 with local display 5654021D-L-101
PulsFox® PMG 20 MS -22 with local display 5654022D-L-101
PulsFox® PMG 20 MS -23 with local display 5654023D-L-101
PulsFox® PMG 20 KX -40 5654040O-L-101
PulsFox® PMG 20 KX -40 with local display 5654040D-L-101
PulsFox® PMG 20 MF -60 5654060O-L-101
PulsFox® PMG 20 MF -61 5654061O-L-101
PulsFox® PMG 20 MF -62 5654062O-L-101
PulsFox® PMG 20 MF -63 5654063O-L-101
PulsFox® PMG 20 MF -60 with local display 5654060D-L-101
PulsFox® PMG 20 MF -61 with local display 5654061D-L-101
PulsFox® PMG 20 MF -62 with local display 5654062D-L-101
PulsFox® PMG 20 MF -63 with local display 5654063D-L-101

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet Guided micropulse level indicators PulsFox® PMG 20 Data sheet PDF
AFRISO Data sheet Guided micropulse level indicators PulsFox® PMG 20
Guided micropulse level indicator PulsFox® PMG 20 Operating instructions PDF
AFRISO Guided micropulse level indicator PulsFox® PMG 20
Application report PulsFox® PMG 20 in mash silo Flyers PDF
AFRISO Application report PulsFox® PMG 20 in mash silo
Professional level measurement solutions for industrial technology and process engineering Flyer PDF
AFRISO Professional level measurement solutions for industrial technology and process engineering
Measuring and control technology for hygienic processes Product range industrial technology PDF
AFRISO Measuring and control technology for hygienic processes
Level measurement Checklists PDF
AFRISO Level measurement
Guided micropulse level indicator PulsFox® PMG 20 Ordering code PDF
AFRISO Guided micropulse level indicator PulsFox® PMG 20
Guided micropulse level indicator PulsFox® PMG 20 Declaration of Conformity PDF
AFRISO Guided micropulse level indicator PulsFox® PMG 20
Guided micropulse level indicator PulsFox® PMG 20 Katalog-Produktinformationen PDF
AFRISO Guided micropulse level indicator PulsFox® PMG 20
PulsFox® PMG 20 level indicators operate on the basis of the guided micropulse principle (TDR, time domain reflectometry). A micropulse is emitted along a probe. The micropulse is surrounded by an electromagnetic field. Reflections of the pulses from objects and surfaces serve as the basis of distance measurement. The pulse's propagation time is directly proportional to the distance between the probe and the surface of the medium. The reflectance of materials depends on the dielectric constant ɛr . Changes of the medium such as, for example vapour, dust or a turbulent surface do not affect the measuring accuracy of this measuring principle. No recalibration is required when a different medium is used. Even if properties such as pressure, temperature and density change, the system operates with high reliability and precision. PulsFox® PMG 20 has no moving parts and is therefore maintenance-free and not subject to wear.
Versions
model / series Probe type
PMG 20 MO-00 mono probe without electrode
PMG 20 MS-20 Mono probe rigid without insulation
PMG 20 MS-21 mono probe with partially insulated probe
PMG 20 MS-22 mono probe rigid with PFA insulation
PMG 20 MS-23 mono probe rigid with FEP insulation
PMG 20 KX-40 Coax probe
PMG 20 MF-60 Mono probe flexible, without insulation, with weight ⌀ 30 mm
PMG 20 MF-61 mono probe flexible, with FEP insulation and weight ⌀ 29 mm (PTFE insulation)
PMG 20 MF-62 Mono probe flexible, without insulation, with mounting eyelet
PMG 20 MF-63 mono probe flexible, with PA insulation and mounting eyelet (not insulated)
Display
5-digit, 9 mm high, yellow Matrix OLED
Resolution 128 x 64 pixels
Max. measuring range
MS-20:
≤ 3,000 mm
MS-21:
≤ 3,000 mm
MS-22:
≤ 2,000 mm
MS-23:
≤ 2,000 mm
KX-40:
≤ 3,000 mm
MF-60:
≤ 40,000 mm
MF-61:
≤ 12,000 mm
MF-62:
≤ 40,000 mm
MF-63:
≤ 40,000 mm
(specify exact probe length when ordering)
Dielectric constant (ɛ<sub>R</sub>) of medium
MS:
≥ 2.1
KX:
≥ 1.8
MF:
≥ 2.1
Measuring accuracy
MS:
± 4 mm ≤ 2 m
± 2 mm > 2 m
KX:
± 3 mm ≤ 2 m
± 2 mm > 2 m
MF:
± 4 mm ≤ 2 m
± 2 mm > 2 m
Operating temperature range
Medium:
-40/+300 °C
Flange:
-40/+85 °C
Ambient:
-30/+70 °C
Process pressure
MS:
Max. 100 bar
KX:
Max. 100 bar
MF:
Max. 10 bar
Process connection
G1B, Stainless steel 316 Ti
Supply voltage
DC 18 – 36 V
Output signal
4–20 mA/HART, 2-wire
Material
Probe head:
Aluminium die cast
Probe
MS:
Stainless steel 316 Ti
KX:
Stainless steel 316 Ti
MF:
Stainless steel 316 L
Degree of protection
IP 67 (EN 60529)
Electrical connection
Cable gland M16 x 1.5

Options

  • Other process connections
  • FEP/PFA coatings
  • EX version Ex II 1/2 G Ex ia IIB T5 Ga/Gb
Guided micropulse level indicator PulsFox® PMG 20
Guided micropulse level indicator PulsFox® PMG 20
AFRISO
Dimensions (in mm)
PulsFox® PMG 20 high temperature version
PulsFox® PMG 20 high temperature version
AFRISO
Dimensions (in mm)
PulsFox® PMG 20 with process connection TriClamp 1"
PulsFox® PMG 20 with process connection TriClamp 1"
AFRISO
Dimensions (in mm)
PulsFox® PMG 20 MS - 20-with rigid mono probe
PulsFox® PMG 20 MS - 20-with rigid mono probe
AFRISO
Dimensions (in mm)
  1. Electrode holder
  2. Electrode
PulsFox® PMG 20 MS - 21 with rigid mono probe (partially insulated)
PulsFox® PMG 20 MS - 21 with rigid mono probe (partially insulated)
AFRISO
Dimensions (in mm)
PulsFox® PMG 20 MS - 22 with rigid mono probe (PFA insulation)
PulsFox® PMG 20 MS - 22 with rigid mono probe (PFA insulation)
PulsFox® PMG 20 MS - 23-with rigid mono probe (FEP insulation)
AFRISO
Dimensions (in mm)
PulsFox® PMG 20 KX - 40 with coax probe
PulsFox® PMG 20 KX - 40 with coax probe
AFRISO
Dimensions (in mm)
  1. 4 x opening
PulsFox® PMG 20 MF - 61 with flexible mono probe (FEP/PTFE insulation)
PulsFox® PMG 20 MF - 61 with flexible mono probe (FEP/PTFE insulation)
AFRISO
Dimensions (in mm)
PulsFox® PMG 20 - 62/63 mounting eyelet
PulsFox® PMG 20 - 62/63 mounting eyelet
AFRISO
Dimensions (in mm)
  1. Mounting
PulsFox® PMG 20 MF - 60/62/63 with flexible mono probe
PulsFox® PMG 20 MF - 60/62/63 with flexible mono probe
AFRISO
Dimensions (in mm)