Pressure transducers HydroFox® DMU 07 for level measurement

 ANW 62690 62700 62710 62720 62730 62740 62750 62760 62770 62780 62790 62800 62810 62820 62840 62850 62860 62870 62880 62890 62900 62910 62920 62930 62940 62950 62960 62970  ANW 62690 62700 62710 62720 62730 62740 62750 62760 62770 62780 62790 62800 62810 62820 62840 62850 62860 62870 62880 62890 62900 62910 62920 62930 62940 62950 62960 62970
 ANW 62690 62700 62710 62720 62730 62740 62750 62760 62770 62780 62790 62800 62810 62820 62840 62850 62860 62870 62880 62890 62900 62910 62920 62930 62940 62950 62960 62970 <div class="gallery-information"> <b>Legend:</b> <ol> <li>Digital display unit DA 12</li> <li>Signalling device</li> <li>Pressure transducers HydroFox<sup>®</sup> DMU07</li> </ol> </div>
 BEF 62840 62850 62860 62870 62880 62890 62900 62910 62920 62930 62940 62950 62960 62970  BEF 62840 62850 62860 62870 62880 62890 62900 62910 62920 62930 62940 62950 62960 62970
 BEF 62840 62850 62860 62870 62880 62890 62900 62910 62920 62930 62940 62950 62960 62970 <div class="gallery-information"> <p> <strong>DMU 07 FG - connection G1½B field housing</strong> </p> <p>Dimensions (in mm)</p> <b>Legend:</b> <ol> <li>Cable outlet</li> </ol> </div>
 SAR 62690 62700 62710 62720 62730 62740 62750 62760 62770 62780 62790 62800 62810 62820 object_image_64265imagemain_en
 ANW 62690 62700 62710 62720 62730 62740 62750 62760 62770 62780 62790 62800 62810 62820 62840 62850 62860 62870 62880 62890 62900 62910 62920 62930 62940 62950 62960 62970
 BEF 62690 62700 62710 62720 62730 62740 62750 62760 62770 62780 62790 62800 62810 62820
 BEF 62840 62850 62860 62870 62880 62890 62900 62910 62920 62930 62940 62950 62960 62970
Data sheet Pressure transducers HydroFox® DMU 07 for level measurement
AFRISO Data sheet Pressure transducers HydroFox® DMU 07 for level measurement

Versions

Type Connection Measuring range Part no. Remember
HydroFox® DMU 07 G1½B 0/40 mbar 31789
HydroFox® DMU 07 G1½B 0/60 mbar 31790
HydroFox® DMU 07 G1½B 0/100 mbar 31791
HydroFox® DMU 07 G1½B 0/160 mbar 31792
HydroFox® DMU 07 G1½B 0/200 mbar 31793
HydroFox® DMU 07 G1½B 0/250 mbar 31794
HydroFox® DMU 07 G1½B 0/400 mbar 31795
HydroFox® DMU 07 G1½B 0/600 mbar 31796
HydroFox® DMU 07 G1½B 0/1 bar 31797
HydroFox® DMU 07 G1½B 0/1.6 bar 31798
HydroFox® DMU 07 G1½B 0/2 bar 31799
HydroFox® DMU 07 G1½B 0/4 bar 31800
HydroFox® DMU 07 G1½B 0/6 bar 31801
HydroFox® DMU 07 G1½B 0/10 bar 31802
HydroFox® DMU 07 FG G1½B 0/40 mbar 31821
HydroFox® DMU 07 FG G1½B 0/60 mbar 31805
HydroFox® DMU 07 FG G1½B 0/100 mbar 31547
HydroFox® DMU 07 FG G1½B 0/160 mbar 31806
HydroFox® DMU 07 FG G1½B 0/200 mbar 31548
HydroFox® DMU 07 FG G1½B 0/250 mbar 31807
HydroFox® DMU 07 FG G1½B 0/400 mbar 31549
HydroFox® DMU 07 FG G1½B 0/600 mbar 31808
HydroFox® DMU 07 FG G1½B 0/1 bar 31550
HydroFox® DMU 07 FG G1½B 0/1.6 bar 31809
HydroFox® DMU 07 FG G1½B 0/2 bar 31551
HydroFox® DMU 07 FG G1½B 0/4 bar 31552
HydroFox® DMU 07 FG G1½B 0/6 bar 31810
HydroFox® DMU 07 FG G1½B 0/10 bar 31553

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet Pressure transducers HydroFox® DMU 07 for level measurement Data sheet PDF
AFRISO Data sheet Pressure transducers HydroFox® DMU 07 for level measurement
Pressure transmitters DMU 03…Ex, DMU 04…Ex, DMU 05…Ex, DMU 07…Ex Operating instructions PDF
AFRISO Pressure transmitters DMU 03…Ex, DMU 04…Ex, DMU 05…Ex, DMU 07…Ex
Pressure transmitters / screw-in probes DMU 01, DMU 01 K, DMU 03, DMU 03 HD, DMU 04, DMU 05P, DMU 07, DMU 07 FG Operating instructions PDF
AFRISO Pressure transmitters / screw-in probes DMU 01, DMU 01 K, DMU 03, DMU 03 HD, DMU 04, DMU 05P, DMU 07, DMU 07 FG
Electronic pressure measurement - pressure transducers DMU series Product range industrial technology PDF
AFRISO Electronic pressure measurement - pressure transducers DMU series
Measuring and control technology for hygienic processes Product range industrial technology PDF
AFRISO Measuring and control technology for hygienic processes
Enquiry pressure transducers DMU Checklists PDF
AFRISO Enquiry pressure transducers DMU
Pressure transducers HydroFox® DMU 07, 09 Declaration of Conformity PDF
AFRISO Pressure transducers HydroFox® DMU 07, 09
NA Pressure transducers HydroFox® DMU 08 Options PDF
AFRISO NA Pressure transducers HydroFox® DMU 08
Pressure transducers convert physical pressure into an electrical signal proportional to the pressure. HydroFox® DMU 07 uses a capacitance ceramic measuring cell.
Measuring accuracy
Deviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
< ± 0.35 % FSO
Measuring range
See ordering table
Overpressure safety
≤ 400 mbar:
At least 25 x FS
> 400 mbar:
At least 3 x FS
Operating temperature range
Medium:
-40/+125 °C
Ambient:
-40/+85 °C
Storage:
-40/+100 °C
Temperature error band
≤ 0.1 % FSO/10 K In compensated range -20/+80 °C
Dynamic characteristics
Response time:
≤ 200 ms
Process connection
G1½B with flush diaphragm
Material
Housing:
Stainless steel 316 L
Pressure connection:
Stainless steel 316 L
Diaphragm:
Ceramic (Al2O3 96 %)
Seal:
FKM (Viton)
Supply voltage
DC 9 – 32 V
Output signal
2-wire, 4–20 mA
Load
R<sub>Max</sub> = [(UB – UB<sub>Min</sub>)/0.02 A] Ω
Current input
< 21 mA
Electrical protection
Short circuit proof and protected against reverse polarity
Electrical connection
Connector and junction box as per ISO 4400 (DIN 43650-A)
Degree of protection
IP 65 (EN 60529)
CE conformity
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Pressure Equipment Directive 2014/68/EU

Options

  • Pressure connection made of PVDF
  • Other seal materials
  • Field housing (stainless steel 303)
  • Higher accuracy
  • Other output signals
  • Ex version<br/>Ex II 1/2G Ex ia IIC T4 Ga/Gb<br/>Ex II 1G Ex ia IIC or IIB T6 or T4 Ga (metal housing)<br/>Ex II 1/2D Ex ia IIIC T 110 °C Da/Db<br/>Ex II 10 Ex ia IIIC T 110 °C (metal housing)
DMU 07 - connection G1½B DIN 3852 type E
DMU 07 - connection G1½B DIN 3852 type E
Connector and junction box ISO 4400, pressure connection made of stainless steel
AFRISO
Dimensions (in mm)
DMU 07 FG - connection G1½B field housing
DMU 07 FG - connection G1½B field housing
AFRISO
Dimensions (in mm)
  1. Cable outlet
wiring diagram
wiring diagram
AFRISO
3-wire 0-10 V
wiring diagram
wiring diagram
AFRISO
2-wire, 4-20 mA