Digital display and control unit VarioFox® 24

AFRISO Digitales Anzeige- und Regelgerät VarioFox 24 VOR 960 object_image_77537imagemain_en AFRISO Digitales Anzeige- und Regelgerät VarioFox 24 VOR 960 object_image_77537imagemain_en
Digitales Anzeige- und Regelgerät VarioFox 24
AFRISO Digitales Anzeige- und Regelgerät VarioFox 24 VOR 960 object_image_77537imagemain_en
AFRISO Digitales Anzeige- und Regelgerät VarioFox 24 SAL 960 AFRISO Digitales Anzeige- und Regelgerät VarioFox 24 SAL 960
Digitales Anzeige- und Regelgerät VarioFox 24
AFRISO Digitales Anzeige- und Regelgerät VarioFox 24 SAL 960
AFRISO Hydrostat. Füllstandmessgerät HydroFox DMU 08 0/100mbar ANW 460 470 480 490 500 960 67740 67750 67760 67770 67780 67790 67800 67810 67820 67830 67840 67850 67860 67870 67880 67890 67900 18910 18920 18930 18940 18950 18960 AFRISO Hydrostat. Füllstandmessgerät HydroFox DMU 08 0/100mbar ANW 460 470 480 490 500 960 67740 67750 67760 67770 67780 67790 67800 67810 67820 67830 67840 67850 67860 67870 67880 67890 67900 18910 18920 18930 18940 18950 18960
Hydrostat. Füllstandmessgerät HydroFox DMU 08 0/100mbar
AFRISO Hydrostat. Füllstandmessgerät HydroFox DMU 08 0/100mbar ANW 460 470 480 490 500 960 67740 67750 67760 67770 67780 67790 67800 67810 67820 67830 67840 67850 67860 67870 67880 67890 67900 18910 18920 18930 18940 18950 18960 <div class="gallery-information"> <b>Legend:</b> <ol> <li>Junction box with pressure relief port</li> <li>Digital display and control unit VarioFox 12/14</li> <li>Signalling device</li> <li>HydroFox<sup>®</sup> DMU 08</li> </ol> </div>
AFRISO Digitales Anzeige- und Regelgerät VarioFox 24 VOR 960 object_image_77537imagemain_en
AFRISO Digitales Anzeige- und Regelgerät VarioFox 24 SAL 960
AFRISO Hydrostat. Füllstandmessgerät HydroFox DMU 08 0/100mbar ANW 460 470 480 490 500 960 67740 67750 67760 67770 67780 67790 67800 67810 67820 67830 67840 67850 67860 67870 67880 67890 67900 18910 18920 18930 18940 18950 18960
Data sheet digital display and control unit VarioFox® 24
AFRISO Data sheet digital display and control unit VarioFox® 24

Versions

Part no. Remember
Digital display and control unit VarioFox® 24 31248

Blue part no. = in-stock items

Description Format Language Download / Link
Data sheet digital display and control unit VarioFox® 24 Data sheet PDF
AFRISO Data sheet digital display and control unit VarioFox® 24
Display and control unit VarioFox 24 Operating instructions PDF
AFRISO Display and control unit VarioFox 24
Display and control unit VarioFox® 24 Declaration of Conformity PDF
AFRISO Display and control unit VarioFox® 24
Compact, ready-to-connect display and control unit in a robust wall-mounting housing. With integrated sensor supply and 4 relay outputs. Together with a transducer (e.g. for pressure, temperature, level, etc.), VarioFox® forms an autonomous measuring and control system. VarioFox® is universally applicable and freely configurable.
Display
Multi-coloured, backlit graphical display (50 x 30 mm),
Blue = Operation,
Red = Alarm,
Green = setup,
Display (5 digits),
User interface language selectable: English, German, French, Italian,
Start and end values as well as comma are scalable as required
Linearity
± 0.1 % v. Mw.
Resolution
10 Bit, Decimal point position can be set as required
Operating temperature range
Ambient:
0/50 °C
Storage:
-20/+65 °C
Supply voltage
AC 50 – 253 V, 4.2 VA
DC 20 – 253 V, 2.7 W
Sensor supply
Integrated, galvanically isolated supply voltage for transducer: DC 17 V/20 mA
Analogue input
All analogue standard signals, e.g. 4–20 mA, 0–20 mA, 0–10 V
Audible alarm
Integrated piezo-buzzer, can be acknowledged
Analogue output 1
0/4–20 mA, galvanically isolated
Analogue output 2
0–10 V, galvanically isolated
Digital interface
Interfaces:
RS 485
With Baud rate adjustment
Switching outputs
Relay contacts:
4 voltage-free changeover contacts
Switching hysteresis adjustable
Contact rating:
AC 250 V, 2 A, 250 VA
DC 250 V, 1 A, 100 W
Housing
Robust wall mounting housing made of impact-resistant plastic (PC)
W x H x D:
175 x 125 x 75 mm
Degree of protection:
IP 65 (EN 60529)
Colour:
Grey (RAL 7035)
Electrical connection:
5 x cable gland M16 x 1.5
Linearisation
Customer-specific linearisation with a max. of 24 points for the indication of volume (e.g. litres) in non-linear tanks. Bearing charts for cylindrical horizontal tanks and spherical tanks are pre-programmed.
Min./max. value memory
The highest and lowest values reached during operation can be displayed.
Data memory
Long-term monitoring data is stored on a memory card (SD/MMC). Memory card not included.